HOW DP50RB CAN SAVE YOU TIME, STRESS, AND MONEY.

How Dp50rb can Save You Time, Stress, and Money.

How Dp50rb can Save You Time, Stress, and Money.

Blog Article

Learn much better diagnostic information and facts as a result of prolonged view on the anatomical composition on all convex probes.

.. Web site 161 The indicator over the printer Faults take place once the adapter turns orange, and the printing printer adapter runs. Disconnect and connect the fails. electrical power adapter, ability to the printer adapter once more, and confirm whether or not the printing is standard following 1 minute. Site 163: Electrical Safety Inspection

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

NOTE: Ensure that you can pull out and push to the IO board sockets vertically when pulling out and assembling the IO board assembly to the placement on the take care of. Get rid of panhead screws with washers M3X6 (four) accustomed to protected the IO board, and after that you may consider out the IO board. Webpage 116 Get rid of panhead screws with washers (two M3X6) which are fastened on the most crucial unit, take out the higher baffle and after that pull out two cables connecting the key board to the facility module assembly.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Purpose: On the back-finish of the key board, a Specific watch IC is used to observe signal voltages  and clock battery electricity which have been provided to the main board by the most crucial unit box electrical power supply module.

Functionality Examination 5.5.1 Check Course of action Resolution Detection depth Geometric Situation Accuracy Blackout area take a look at Record the Examination visuals five.five.2 Test Written content The impression utilized Here's only for reference, stick to the picture impact in the actual Notice: predicament. Needs: Screen: established the contrast and brightness at the clinical application value (or perhaps the default position) Operation surroundings: dark place, simulating the scientific application setting. Web page 76 In issue that the transverse resolution screening targets are horizontally displayed, record the negligible length of two targets which can be clearly acknowledged. Repeat the Procedure over to the transverse resolution screening targets at other depths. As revealed in determine under. Axial resolution ... Page seventy seven When utilizing the convex probe, preserve the transverse resolution screening targets to notice: be exhibited close to the midline. When employing a linear probe with steer function, don't activate the steer function when carry out Dp50rb login the transverse resolution check. Zoom while in the location where the targets Situated if important. The diameter of the goal place at a specific depth is equal for the transverse resolution within the depth. Web page 78 5.

5.2.three Geometric positioning accuracy Longitudinal geometric positioning accuracy  Test Step: Do adjustments as the best way in screening the utmost depth. File the distance by 20mm Every phase to the longitudinal targets line using the measurement caliper; Select the worth with the greatest mistake (to 20mm), calculate the precision using the formula under The measurement caliper should be positioned within the higher fringe of the concentrate on, Take note:... Website page seventy nine Transverse geometric positioning precision  Take a look at Move: Go over the scan floor on the phantom with h2o or pair gel, Carefully Get in touch with the probe with the scan surface area Alter the depth, building the transverse targets to become exhibited within the image. Regulate the focus level to generally be posited beside the transverse targets (the common is just not apparent) Adjust parameters like achieve, TGC, earning each transverse targets to become Obviously exhibited. Webpage 80 five.five.2.4 Blackout Location Take a look at Stage: Deal with the scan area from the phantom with water or pair gel, gently Call the probe While using the scan surface area Modify the depth at a reduce benefit, and set the main target at the nearest destination to the scan area. Lower the value of parameters like AP, Get until the track record noise just may be observed. Webpage eighty one: Software Improve And Servicing

Take note: In advance of uploading the log, ensure the ultrasound system has actually been linked to community, or else, the process could alert “couldn't hook up with server” The server (smtp.

Guidance 4D probe; understand the probe by way of the ID code; swap the 4D drive sign through the  electrical relay to create the 4D probe operate Usually. 4.two.2 Major board The key board could be divided into two areas: entrance-conclude of the principle board and back-finish of the key board.

After you halt the scanning along with the graphic capture, you'll want to electricity from the program and disconnect the procedure from your AC power provide, then pull out AC ability cables. Website page 109: Battery Connecting Board

Mindray’s new technology of black & white ultrasound process, DP-50 Professional, is provided with Highly developed imaging systems enabling further penetration and a lot quicker picture acquisition with greater resolution.

Lower off cable ties connecting the leading unit to the Display screen by diagonal cutting pliers, and afterwards pull out the corresponding cable plugs.

Content Approach Verify the battery periodically : a) Examine if battery could be charged Commonly when electricity-on: That The present capability is one hundred% or ability improves right after a short time signifies which the battery is usually billed Typically.

Report this page